Description |
This issue relates to i21 Help Desk ticket. Click the link below to go to Help Desk ticket.
[HDTN-209077 - Quality Sample save - Date and Time Stamp of Testing dates are changed basis server date and time|https://helpdesk.irely.com/iRelyi21live//#/HD/Ticket/?ticket=HDTN-209077]
Using 17.1.0123.321
Issues with reproduction Steps:
1. Open a Sample in New mode.
2. Testing Start Date, Testing End Date and Sampling End Date are defaulting to current system date based on the local client machine.
!pastedImage_d91357_0.png!
3. Save the sample.
4. Date and Time Stamp gets changed based on the Server Time Zone. (UK time zone)
!pastedImage_d91357_1.png!
5. Since there is 5 hrs difference, it happens to change the date to next day itself if it is being done to later period of the day.
*Expected Result:*
1. Date and Time Stamp should not change based on the server date and time stamp. It should retain the client machine date and time stamp.
|