[Quality] Warning message when input Zero in Differential Above/Below Target

Issue No: CT-7399
Created 6/16/2022 2:04:12 PM
Type Bug-QC
Priority Critical
Status Closed
Resolution Fixed
Fixed Version 22.1
Description Pre condition:   Item Quality Criteria Setup   |Property Name|Target Value|Min Value|Max Value|Factor Over Target|Escalate By|Differential Above Target|Factor Under Target|Differential Below Target|Cost Type|Currency|UOM| |Humidity%|600|550|850|1.5|Exact Factor|9.2|1.5|9.2|Per Unit|USD|KG| |Density|600|550|850|1.5|Prorata|9.2|1.5|9.2|Percentage|USD|KG|   Steps   1. Create Contract 2. Add Quality Sample 3. Go to Test Detail tab 4. Details from Item Quality Premium Criteria setup is display 5. Save and Approve Quality Sample > Check Impact Pricing 6. Go to Contract > Open Sequence 7. Go to Quality tab > Quality details is displayed 8. In Density entry, update Differential Above Target to '0'     Issue:   A warning message prompts.   !pastedImage_d188050_0.png|height=278,width=562!   !pastedImage_d188050_1.png|height=675,width=562!   Accepted:   Should not prompt a warning message. Instead, add a validation that Differential Above/Below Target cannot be zero